I have a HP Gen10 server with 50 disks hanging on two different controllers P408i, P408e and P208i) (and a couple of expanders). Some of the disks are in an external enclosure. ses0: <HPE 12G SAS Exp Card 5.08>; ID: 51402ec010b61100 Desc Dev Model Ident Size/Status - - - - Not Installed - da0 HP EG001200JWFVA 48D0A19BFQXE1815 1T - da1 HP EG001200JWFVA 48D0A1BTFQXE1815 1T - da2 HP EG001200JWFVA 48D0A1GGFQXE1815 1T - da3 HP EG001200JWFVA 48D0A1B6FQXE1815 1T - da4 HP EG001200JWFVA 48D0A1AGFQXE1815 1T - da5 HP EG001200JWFVA 48D0A1EQFQXE1815 1T - da6 HP EG001200JWFVA 48D0A1H2FQXE1815 1T - da7 HP EG001200JWFVA 48D0A1FMFQXE1815 1T - da8 HP EG001200JWJNQ WFK1F14Y 1T - da9 HP EG001200JWJNQ WFK248J7 1T - da10 HP EG001200JWJNQ WFK2MLXX 1T - da11 HP EG001200JWJNQ WFK2FRNL 1T - da12 HP EG001200JWJNQ WFK12X9N 1T - da13 HP EG001200JWJNQ WFK2LREQ 1T - da14 HP EG001200JWJNQ WFK2H5CH 1T - da15 HP EG001200JWJNQ WFK2ER85 1T - da16 HP EG001200JWJNQ WFK3JD0N 1T - da17 HP EG001200JWJNQ WFK3JBDM 1T - da18 HP EG001200JWJNQ WFK3JD8E 1T - da19 HP EG001200JWJNQ WFK3ES09 1T - da20 HP EG001200JWJNQ WFK3JCPY 1T - da21 HP EG001200JWJNQ WFK3JBDQ 1T - da22 HP EG001200JWJNQ WFK3JB3X 1T - da23 HP EG001200JWJNQ WFK3ERTQ 1T - - - - Not Installed - - - - Not Installed - - - - Not Installed - - - - Not Installed ses1: <HPE E208i-p SR Gen10 3.53>; ID: 51402ec011040770 Desc Dev Model Ident Size/Status Internal Device - - - OK Temperatures: Controller Temperature Sensors : 69 C, emc_1464_int:0:7:Vendor defined : 44 C, emc_1464_ext1:1:1:Chip ASIC : 69 C, emc_1464_ext2:2:8:Vendor define : 58 C, emc_1464_ext3:3:6:Vendor define : 51 C ses2: <HPE D3710 5.04>; ID: 5001438041aad880 Desc Dev Model Ident Size/Status {"Name":"Drive bay"} - - - Not Installed {"Name":"DriveBay1"} da24 HP EG001200JWJNQ WFK5DDT0 1T {"Name":"DriveBay2"} da25 HP EG001200JWJNQ WFK5FY2N 1T {"Name":"DriveBay3"} da26 HP EG001200JWJNQ WFK5JHPF 1T {"Name":"DriveBay4"} da27 HP EG001200JWJNQ WFK5FV96 1T {"Name":"DriveBay5"} da28 HP EG001200JWJNQ WFK5FV9P 1T {"Name":"DriveBay6"} da29 HP EG001200JWJNQ WFK5FWHX 1T {"Name":"DriveBay7"} da30 HP EG001200JWJNQ WFK5JH9R 1T {"Name":"DriveBay8"} da31 HP EG001200JWJNQ WFK5B2XA 1T {"Name":"DriveBay9"} da32 HP EG001200JWJNQ WFK72ZM9 1T {"Name":"DriveBay10"} da33 HP EG001200JWJNQ WFK6RNDD 1T {"Name":"DriveBay11"} da34 HP EG001200JWJNQ WFK72VXL 1T {"Name":"DriveBay12"} da35 HP EG001200JWJNQ WFK6RMHA 1T {"Name":"DriveBay13"} da36 HP EG001200JWJNQ WFK72ZLX 1T {"Name":"DriveBay14"} da37 HP EG001200JWJNQ WFK6S3ST 1T {"Name":"DriveBay15"} da38 HP EG001200JWJNQ WFK72ZH8 1T {"Name":"DriveBay16"} da39 HP EG001200JWJNQ WFK72H6S 1T {"Name":"DriveBay17"} da40 HP EG001200JWJNQ WFK7Y2H2 1T {"Name":"DriveBay18"} da41 HP EG001200JWJNQ WFK826HG 1T {"Name":"DriveBay19"} da42 HP EG001200JWJNQ WFK86CZM 1T {"Name":"DriveBay20"} da43 HP EG001200JWJNQ WFK89JCS 1T {"Name":"DriveBay21"} da44 HP EG001200JWJNQ WFK827M0 1T {"Name":"DriveBay22"} da45 HP EG001200JWJNQ WFK89LYY 1T {"Name":"DriveBay23"} da46 HP EG001200JWJNQ WFK7ZC2A 1T {"Name":"DriveBay24"} da47 HP EG001200JWJNQ WFK7Y2HJ 1T {"Name":"DriveBay25"} - - - Not Installed Temperatures: {"Name":"Temperature sensor"} : 46 C, {"Name":"LocalIoModule-Sensor[0]"} : 29 C, {"Name":"LocalIoModule-Sensor[1]"} : 29 C, {"Name":"LocalExpander-CpuSensor[0]"} : 46 C, {"Name":"PartnerIoModule-Sensor[0]"}: 29 C, {"Name":"PartnerIoModule-Sensor[1]"}: 30 C, {"Name":"PartnerExpander-CpuSensor[0]"} : 46 C, {"Name":"PowerSupply[1]-InletSensor[0]"}: 31 C, {"Name":"PowerSupply[1]-Sensor[0]"} : 36 C, {"Name":"PowerSupply[2]-InletSensor[0]"}: 29 C, {"Name":"PowerSupply[2]-Sensor[0]"} : 33 C, {"Name":"Backplane-Sensor[0]"} : 26 C, {"Name":"Backplane-Sensor[1]"} : 26 C, {"Name":"Backplane-Sensor[2]"} : 27 C, {"Name":"Backplane-Sensor[3]"} : 26 C, {"Name":"Backplane-Sensor[4]"} : 25 C ses3: <HPE P408e-p SR Gen10 3.53>; ID: 51402ec01361cce0 Desc Dev Model Ident Size/Status Internal Device - - - OK Temperatures: Controller Temperature Sensors : 68 C, emc_1464_int:0:7:Vendor defined : 52 C, emc_1464_ext1:1:1:Chip ASIC : 68 C, emc_1464_ext2:2:8:Vendor define : 53 C, emc_1464_ext3:3:6:Vendor define : 58 C ses4: <HPE P408i-a SR Gen10 3.53>; ID: 51402ec010284310 Desc Dev Model Ident Size/Status Internal Device - - - OK ArrayElement0000 da48 HP EG000300JWFVB 48B0A025FQVE1815 300G NoDrive000000001 - - - Not Installed ArrayElement0002 da49 HP EG000300JWFVB 48B0A015FQVE1815 300G NoDrive000000003 - - - Not Installed Temperatures: Controller Temperature Sensors : 58 C, emc_1464_int:0:7:Vendor defined : 48 C, emc_1464_ext1:1:1:Chip ASIC : 58 C, emc_1464_ext2:2:8:Vendor define : 48 C I tried upgrading this server from 12.3-p5 to 13.1-p2. Upon booting the the kernel, it panics rather late in the boot process, with this: panic: make_dev_alias_v: bad is_name (errror=22, si_name=enc0n5001438041aad8ba/type@0/slot@1/elmdesc@("Name": DriveBay1")/pass27 This also happens with FreeBSD 13.0 It looks like it does not like my enclosure.
This is a duplicate of https://bugs.freebsd.org/bugzilla/show_bug.cgi?id=264513 which has been merged to stable/13.
*** This bug has been marked as a duplicate of bug 264513 ***